China Suppliers Factory Power Conversion System Inverter AC/DC Dual Backup for Auxiliary Power Supply 100KT 110KT 125KT
The core equipment in an energy storage system and is often referred to as the "brain" of the system. Its main function is to convert power between alternating current (AC) and direct current (DC), enabling the control and dispatch of electrical energy.
AC/DC Conversion (Rectification/Inversion):
Charging (AC → DC): When there is excess power from the grid (or AC power generated by a PV inverter), the PCS converts it into DC electricity to store in the batteries. This process is called rectification.
Discharging (DC → AC): When electricity is needed, the PCS converts the DC power from the batteries into AC power and supplies it to the grid or to the load (electrical equipment). This process is called inversion.
The PCS enables the energy storage system to switch between grid-tied mode (connected to the grid) and off-grid mode (operating independently, e.g., in a microgrid) as needed.
| Model | Mars-125KT | Mars-110KT | Mars-100KT |
|---|---|---|---|
| DC side parameters | |||
| Maximum DC voltage | 1,000V | 1,000 V | 1,000v |
| Minimum DC voltage[1] | 580V | 580V | 580V |
| DC voltage operating range | 350-1000 V | 350-1000V | 350-1000v |
| Maximum DC current | 216A | 190A | 173A |
| AC side parameters (grid-connected) | |||
| Rated charging/discharging power | 125kW | 110kW | 100kw |
| Maximum charge and discharge power | 150kW | 132kW | 120kw |
| Rated charge and discharge current | 182A | 160A | 145A |
| Maximum charge-discharge current | 217A | 192A | 174A |
| Rated grid voltage | 400V | 400V | 400V |
| Permissible grid voltage range | 300-460 V | 300-460 V | 300-460v |
| Rated grid frequency | 50Hz/60Hz | 50Hz/60Hz | 50Hz/60Hz |
| Current total harmonic distortion rate | <3% (at rated power) | <3% (at rated power) | <3% (at rated power) |
| Power factor | > 0.99 | > 0.99 | > 0.99 |
| Power factor range | -1~1 | -1~1 | -1~1 |
| Overload capacity | 1.2 Pn, continuous for 1 minute | 1.2 Pn, continuous for 1 minute | 1.2 Pn, continuous for 1 minute |
| AC side parameter (off-grid) | |||
| Rated input voltage | 400V | 400V | 400V |
| Voltage deviation | ±2% | ±2% | ±2% |
| Total harmonic distortion rate | <3% (linear load) | <3% (linear load) | <3% (linear load) |
| Efficiency | |||
| Maximum efficiency | 98.9% | 98.9% | 98.9% |
| Protection | |||
| DC reverse polarity protection | Supported | Supported | Supported |
| AC short-circuit protection | Supported | Supported | Supported |
| AC output overcurrent protection | Supported | Supported | Supported |
| Surge protection | Level 2 | Level 2 | Level 2 |
| Insulation resistance monitoring | Supported | Supported | Supported |
| Temperature protection | Supported | Supported | Supported |
| Basic parameters | |||
| Topology | Without transformer | Without transformer | Without transformer |
| Ambient temperature | -40℃~+60℃ | -40℃~+60℃ | -40℃~+60℃ |
| Protection level | IP20 (module and battery pack integrated solution, system protection level is IP54 or above) | IP20 (module and battery pack integrated solution, system protection level is IP54 or above) | IP20 (module and battery pack integrated solution, system protection level is IP54 or above) |


What is a Power Conversion System (PCS) Inverter?
How does the AC/DC conversion process work in this system?
Does the Mars series support both grid-tied and off-grid modes?
What monitoring and remote control interfaces are supported?
What safety and protection features are integrated?
Can the Mars PCS handle unbalanced loads?
Get in touch
We're Ready To Assist You Anytime