Specifications
| Type | GT-PCTC-1.5KW | GT-PCTC-2KW | GT-PCTC-3KW | GT-PCTC-5KW | |||
| Wind turbine rated power | 1.5KW | 2KW | 3KW | 5KW | |||
| Wind turbine rated voltage | AC220V-240V | AC220V-240V | AC220V-380V | AC380-450V | |||
| Function | Rectifier,Control,DC output | ||||||
| Automatic protection function | Over voltage protection, Grid cut off protection, Regulated supply output, Arrester | ||||||
| Manual function | Manual brake, Reset, Emergency switch | ||||||
| Display mode | LCD Touch Screen | ||||||
| Display content (larger one) | Generator speed(rpm),Input voltage (Vdc), Input current(Vac) ,Output power(kW), Grid voltage (Vac),Grid current(A), Power generate today(kWh),Power generate this month, Power generate last month, Power generate this year, Power generate last year,Power Curve setting. | ||||||
| PWM constant voltage | ≥400dc | ≥400dc | ≥400dc | ≥700dc | |||
| Wind turbine 3-phase dump load voltage | 450±5Vdc | 450±5Vdc | 450±5Vdc | 750±5Vdc | |||
| 3-phase dump load time-lapse | 12-20 min | 12-20 min | 12-20 min | 12-20 min | |||
| Environment temperature | -30-60°C | ||||||
| Relative humidity | <90% No condensation | ||||||
| Noise (1m) | <40dB | ||||||
| Degree of protection | IP20(Indoor) IP65 (Outdoors) | ||||||
| Cooling method | Forced air cooling | ||||||
| Communication interface (optional) | RS485/USB/GPRS/WIFI/Ethernet | ||||||
| Size of the controller (mm) | 500*395*270 | 500*395*270 | 500*395*270 | 500*395*270 | |||
| Controller Weight | 20Kg | 20Kg | 22Kg | 22Kg | |||
| Dump load Size (mm) | 620*215*190 | 620*215*190 | 620*215*190 | 620*215*190 | |||
| Dump load Weight | 14Kg | 14Kg | 14Kg | 30Kg | |||
| Type | GT-PCTC-10KW | GT-PCTC-20KW | GT-PCTC-30KW | GT-PCTC-50KW | GT-PCTC-100KW | ||
| Wind turbine rated power | 10KW | 20KW | 30KW | 50KW | 100KW | ||
| Wind turbine rated voltage | AC380-520V | ||||||
| Function | Rectifier,Control,DC output | ||||||
| Automatic protection function | Over voltage protection, Grid cut off protection, Regulated supply output, Arrester | ||||||
| Manual function | Manual brake, Reset, Emergency switch | ||||||
| Display mode | LCD Touch Screen | ||||||
| Display content (larger one) | Generator speed(rpm),Input voltage (Vdc), Input current(Vac) ,Output power(kW), Grid voltage (Vac),Grid current(A), Power generate today(kWh),Power generate this month, Power generate last month, Power generate this year, Power generate last year,Power Curve setting. | ||||||
| PWM constant voltage | ≥700dc | ≥700dc | ≥700dc | ≥700dc | ≥700dc | ||
| Wind turbine 3-phase dump load voltage | 750±5Vdc | 750±5Vdc | 750±5Vdc | 750±5Vdc | 750±5Vdc | ||
| Wind turbine 3-phase dump load time-lapse | 12-20 min | 12-20 min | 12-20 min | 12-20 min | 12-20 min | ||
| Environment temperature | -30-60°C | ||||||
| Relative humidity | <90% No condensation | ||||||
| Noise (1m) | <40dB | ||||||
| Degree of protection | IP20(Indoor) IP65 (Outdoors) | ||||||
| Cooling method | Forced air cooling | ||||||
| Communication interface (optional) | RS485/USB/GPRS/WIFI/Ethernet | ||||||
| Size of the controller (mm) | 550*395*270 | 600*500*1200 | 600*500*1200 | 930*580*430mm | 1100*600*1800 | ||
| Controller Weight | 25Kg | 66Kg | 68Kg | 50KG | 406KG | ||
| Dump load Size (mm) | 690*520*270 | 690*530*520 | 710*890*590 | 710*890*590 | Dumpload built-in | ||
| Dump load Weight | 45Kg | 55Kg | 55Kg | 55Kg | Dumpload built-in | ||
Leading Features
System Solution
Product Display
FAQS
Compared with PV grid-tied inverters, small wind turbine grid-tied inverters market supply have following problem :
- ◐ Few professional small wind turbine grid-tied invertor factories
- ◐ Small wind turbine grid-tied invertors are several times more expensive than PV inverters
- ◐ Quality is unstable, no after-sale service
- ◐ Low efficiency
- ◐ No grid connection certification
GREEF GT-PCTC series controller can works together with GROWATT,DEYE,SOLIS brand PV grid-tied inverter , track and control the grid-tied power all the time.User can setting the wind turbine working power curve by themselves on the screen according to the wind turbine performance . it can Inspection the generator speed and according to the setting power curve speed VS power to let the invertor working accordingly
PWM Constant voltage + Three-phase dump load brake
①PWM constant voltage is control the wind turbine output not exceed 120% of the wind turbine rated power .
②If exceeding of PWM’s capacity, it means the wind turbine is over speed , then the three-phase dump load system will brake the wind turbine automatically & immediately.After10- 20 minutes, the brake will release , then the wind turbine will re-start to generation power.
③When meet strong wind , the controller can conduct constant voltage output to ensure the inverter safety running.
④When grid-tied inverter disconnected, the controller can conduct constant voltage output and wait for inverter resumption.
⑤When the grid is cut off, the three-phase dump load will automatically start to brake the wind turbine and let the inverter stop output to grid. When the grid recover, the controller will also recover the wind turbine.
❶Surge protector: Limit the transient over-voltage that breaks into the wind turbine's power line to a voltage range that the equipment can withstand, or discharge a powerful lightning current into the ground to protect the equipment from lightning strikes.
❷Emergency stop switch: in case of emergency, press down the emergency stop button in the front panel to cut off all power supply of the controller and the wind turbine will immediately brake(three-phase dump load).
❸Manual Brake switch: To using this switch, the wind turbine will brake all the time .(three-phase dump load).
❶Modbus Communication protocol is available. Convenient to carry out the secondary development.
❷RS485 is available. Adjusting the technical specification via RS485
❸Support WIFI and LAN remote monitoring and control. Customers can monitor the real-time working state of the on grid wind power system via PC and mobile and query history working sate. Both Android and OS are compatible in Mobile.