+86 15166057722
0102030405
China AFVR Series Frequency & Voltage Regulator - Reliable AC Power Supply Factory & Suppliers for Sensitive Equipment
Product Advantage
1. Advanced Technology: SPWM IGBT High-Frequency Inverter
2. Internal Structure: AC-DC-AC
3. Pure Sine Wave Output
4. Wide Range of Voltage & Frequency Input
5. High Precision
6. PLC Touch Screen Display
7. Output with Isolated Transformer
8. Work well with permanent magnet generator
9. Output voltage & frequency customized
10. Remote monitoring by RS485 WIFI or GPRS
Technical Specification
| MODEL | AFVR-315 | AFVR-316 | AFVR-3110 | AFVR-3115 | AFVR-3120 | AFVR-3130 | AFVR-3150 | AFVR-31100 | AFVR-31200 | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Power Capacity (VA) | 5kVA | 6kVA | 10kVA | 15kVA | 20kVA | 30kVA | 50kVA | 100kVA | 200kVA | ||||||||
| Circuit Mode | IGBT/SPWM pulse width adjustment mode | ||||||||||||||||
| AC INPUT | Voltage | Standard 265V-495V (Or ±30% of Generator rated voltage) | |||||||||||||||
| Frequency | 30-100Hz | ||||||||||||||||
| Phase | Three Phase | ||||||||||||||||
| AC OUTPUT | Voltage | 110/120/220V±1% (customized) | |||||||||||||||
| Frequency | 50Hz/60Hz Adjustable | ||||||||||||||||
| Phase | Single Phase | ||||||||||||||||
| Frequency Stability | ≤ ±0.01% | ||||||||||||||||
| Voltage Stability | ≤ 1% | ||||||||||||||||
| Wave Distortion | ≤ 2% | ||||||||||||||||
| Reaction Time | ≤ 2mS | ||||||||||||||||
| Overload Capacity | 110%, 3 minutes; 200%, 10 seconds | ||||||||||||||||
| Dynamic Voltage Transient Range | 2% (0~100% load change) | ||||||||||||||||
| THDV | THD < 3% (nonlinear load) | ||||||||||||||||
| DPI (Dots per inch) | Display Window | High precision LCD touch screen display | |||||||||||||||
| Frequency Meter | 0.1Hz | ||||||||||||||||
| Voltage Meter | 0.1V | ||||||||||||||||
| Current Meter | 0.1A | ||||||||||||||||
| Power Meter | 0.1W | ||||||||||||||||
| Efficiency | ≥ 90% suitable for inductive load, capacitive load, resistive load and any mixed load. | ||||||||||||||||
| Protection Function | The importation of non-fuse switch, without output fuse switch, the electronic circuit to detect over-voltage Express. Over voltage, over current, over temperature, over load, short circuit, and automatic alarm. | ||||||||||||||||
| Insulation Reactance | 500Vdc 20MΩ | ||||||||||||||||
| Pressure Endurance Insulation | 1500Vac/5mA/1min | ||||||||||||||||
| Cooling Model | Compulsive fan cooling | ||||||||||||||||
| Working Temperature | -10℃ - 45℃ | IP22 | ||||||||||||||||
| Relative Humidity | 0-90% (No condensing) | ||||||||||||||||
| Altitude | 1500 meters | ||||||||||||||||
| Dimension | Length (mm) | 350 | 350 | 400 | 400 | 500 | 500 | 650 | 650 | 1910 | |||||||
| Width (mm) | 560 | 560 | 660 | 660 | 830 | 830 | 1420 | 1420 | 1160 | ||||||||
| Height (mm) | 600 | 600 | 700 | 700 | 1000 | 1000 | 1365 | 1365 | 1940 | ||||||||
| Net Weight (Kg) | 60kg | 65kg | 97kg | 107kg | 190kg | 215kg | 290kg | 460kg | 850kg | ||||||||
The above table is only part of the parameters of the product, for more information about other products, please contact us!
System Solution
Optional Function
Industrial grade, WIFI/2G 3G 4G/Ethernet
At the same time, it supports data viewing and management in PC/mobile APP/WeChat/mini programs.etc.
Real-time data viewing, real-time historical curve, data download and push regularly
Product Display
Frequently Asked Questions
1. What is the core technology behind the AFVR series?
The system utilizes an advanced SPWM IGBT high-frequency inverter technology with an AC-DC-AC conversion structure, ensuring high stability, superior precision, and pure sine wave power output.
2. Can this power system work with variable-frequency generators?
Yes, it features a wide input range for both voltage (265V-495V or ±30%) and frequency (30-100Hz), making it fully compatible with permanent magnet generators and unstable grids.
3. Can output voltage and frequency be customized?
Yes, the output voltage is customizable to 110V, 120V, or 220V (±1%), and the frequency can be adjusted flexibly to 50Hz or 60Hz depending on application requirements.
4. What kind of loads can the system support?
With high operating efficiency (≥90%) and an output isolation transformer, it safely drives inductive loads, capacitive loads, resistive loads, and mixed loads with a total harmonic distortion (THD) under 3%.
5. What remote monitoring options are available?
The system supports RS485, WIFI, 2G/3G/4G, and Ethernet communication interfaces, enabling remote data tracking, curve analytics, alarms, and controls via PC platforms or mobile applications.
6. What built-in safety protections does the unit have?
It features integrated comprehensive electronic circuitry for automatic alarm and shutdown against over-voltage, over-current, over-temperature, overload, and short circuits.
Get in touch
We're Ready To Assist You Anytime